Generac 6199 Power Management Module for Synergy Models

Be the first to review this product

Generac 6199 PMM Starter Kit
SKU: 6199

Availability: In stock

$59.99
Generac
Some Manufacturers Require MOA

Your order will be processed within 24 - 48 hours

We ship Fast. For Shipping Time Please read our Shipping Policy

Many products are shipped directly from the manufacturer. Drop-shipped items are subject to manufacturer availability.

For more info about our products. Call us at (866) 462-3581

Have Questions? Contact Us





No Payment Until 2018

Description

Details

The Digital Power Management system consists of two parts. The first is the PMM (Power Management Module) Starter Kit, which includes the easily field installed 24VAC transformer and the first 50 amp, 24VAC actuated PMM. The transformer must be installed in the NEMA 3R Smart Switches to enable the use of PMMs.

The second is the PMM, a 50 Amp, 24VAC actuated contractor housed in a NEMA 3R enclosure for indoor and outdoor installation applications. Through the use of the PMMs in conjunction with any of the 100-800 amp, single phase switches, household or business loads can be intelligently managed enabling the use of a smaller, more efficient generator system. Up to four PMMs can be used with a single switch. Both the PMM Starter Kit and individual PMMs have a one year limited warranty. Note: The Starter Kit and PMM only work with the RTSR and RTSY Transfer Switches **

Specifications

Details

GENERATOR Model 006243-0 (17 KW)
Rated Maximum Continuous Power Capacity (LP) 17,000 Watts
Rated Maximum Continuous Power Capacity (NG) 16,000 Watts
Rated Voltage 240
Rated Maximum Continuous Load Current – 240 Volts 70.8 LP/66.6 NG
Total Harmonic Distortion Less than 5%
Main Line Circuit Breaker 45 Amp
Phase 1
Number of Rotor Poles 2
Rated AC Frequency 60Hz
Battery Requirement (not included) Group 26R 12 Volts and 525 Cold-cranking Amperes Minimum
Unit Weight (Pounds/Kilos)
455/210.9
Dimensions (L” x W” x H”) 48 x 25 x 29
Sound output in dB(A) at 23 ft. with generator operating at normal load 66
 Sound output in dB(A) at 23 ft with generator in Quiet-Test low-speed exercise mode
 60
ENGINE  
Type of Engine GENERAC OHVI V-TWIN
Number of Cylinders 2
Displacement 992cc
Cylinder Block Aluminum w/Cast Iron Sleeve
Valve Arrangement Overhead Valve
Ignition System Solid-state w/Magneto
Governor System Electronic
Compression Ratio 9.5:1
Starter 12 Vdc
Oil Capacity Including Filter Approx. 1.9 Qts./1.8L
Operating RPM 3,600
Fuel Consumption
Natural Gas cu.ft./hr.
1/2 Load
Full Load
Liquid Propane ft3/hr (gal/hr)
1/2 Load
Full Load

 

183
261

59 (1.25)
94 (1.93)

Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 10 to 12 inches of water column for LP gas For BT content, multiply ft3/hr x 2520(LP) or ft3/hr x 1000(NG)
   
CONTROLS  
2-Line Plain Text LCD Display Simple user interface for ease of operation
Mode Switch
-Auto
Automatic Start on Utility failure. 7 day exerciser
-Off Stops unit. Power is removed. Control and charger still operate.
-Manual/Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Programmable start delay between 10-30 seconds Standard
Engine Start Sequence Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration)
Engine Warm-up 5 seconds
Engine Cool-Down 1 minute
Starter Lock-out Starter cannot re-engage until 5 sec. after engine has stopped.
Smart Battery Charger Standard
Automatic Voltage Regulation with Over and Under Voltage Protection Standard
Automatic Low Oil Pressure Shutdown Standard
Overspeed Shutdown Standard, 72Hz
High Temperature Shutdown Standard
Overcrank Protection Standard
Safety Fused Standard
Failure to Transfer Protection Standard
Low Battery Protection Standard
50 Event Run Log Standard
Future Set Capable Exerciser Standard
Incorrect Wiring Protection Standard
Internal Fault Protection Standard
Common External Fault Capability Standard
   
TRANSFER SWITCH
No. of Poles 2
Current Rating (amps) 100
Voltage Rating (VAC) 250
Utility Voltage Monitor (fixed) (Function of Nexus Controller)
-Pick-up
-Dropout
80%
60%
Return to Utility (Function of Nexus Controller)
approx. 13 sec.
Exerciser weekly for 12 minutes (Function of Nexus Controller) Standard
UL Listed Standard
Enclosure Type
NEMA 3R
Withstand Rating (AMPS) 10,000
 Lug Range
400MCM - #4

Reviews

Write Your Own Review

You're reviewing: Generac 6199 Power Management Module for Synergy Models